Date: 16-Jul-2023
SW Rev: V9.05
Description:
1.Stop re-calibration when motor jammed.
2.Change switch binary report to 0x00 if motor is jammed.
Download: BVSZWU_9.05.0_CUSTOS
Date: 16-Jun-2023
SW Rev: V9.04
Description:
1.Send notification “water valve jammed” to controller when the water valve begins moving to open and close state and fails to complete
3.Send notification “state idle (valve jammed)” to controller when water valve reaches a fully open or closed position anytime after a water valve jammed state
Date: 20-Sep-2022
SW Rev: V9.02
Description:
1. Remove battery command class if no SPC connected
Date: 16-Jun-2022
SW Rev: V8.00
Description:
1.Report last known state of water valve prior on power off
Date: 20-Oct-2021
SW Rev: V7.00
Description:
1.Add Configuration Parameter 0x2D – Temperature detection interval in min(s), 0x01 ~ 0x3C (1 ~ 60 mins), default 5 min
Based on this parameter, BVS will determine the temperature once in X minutes and then use other data related to the temperature to decide whether to send a temperature report.
2.Update water valve handle algorithm
3.Add Configuration Parameter 0x16 – Min Pulse Count for calculation, 0x0A ~ 0x63(10 ~ 100), default 0x26(38)
Date: 16-Apr-2021
SW Rev: V6.00
Description:
1.Fix Parameter 0x22 Report Bug
2.Fix Parameter 0x42 Led Display Not work
3.Fix Parameter 0x33 water valve can’t control when its disable
4.Update Temperature Value Calculation
Date: 18-Feb-2021
SW Rev: V5.00
Description:
1.Add SMART POWER CAPSULE (SPC) supported command
1.Support Battery Command Class
2.Support Power Management Notification Command Class
– State idle(0x00)
– Back-up battery is low(0x10)
– Back-up battery disconnected(0x12)
– AC mains disconnected(0x02)
– AC mains re-connected(0x03)
3.Add Configuration Parameter 0x61 – 1/8 turn Auto Control, 0x00~ 0x03 (0x01 Enable for Excluded, 0x01 Enable for Included), default 0x01(Enable for Excluded)
4.Add Configuration Parameter 0x62 – 1/8 turn Auto Control Day, 0x01 ~ 0x1E (1 ~ 30 Days), default value 0x0E (7 days)
5.Add Configuration Parameter 0x71 – Battery Threshold Change Report, (0% ~ 99%), default value 0x0A (10%)
6.Add Configuration Parameter 0x72 – Low Battery level, 0x00 ~ 0x63 (0% ~ 99%), default value 0x1E(30%)
7.Add Configuration Parameter 0x73 – Water Valve Low Battery Control, 0x00(disable)/0x01(enable), default value 0x01 (Enable)
Date: 4-Aug-2020
SW Rev: V3.06
Description:
1. Water Alarm Cancellation – Change to 1 short click from 2 short click
2. Water Alarm Timeout – Water Leak Alarm UI 30 seconds timeout before BVS physical installation is triggered.
3. Leak Sensor Detection – Extended to 1 second detecting time from 10ms
Section: UI / Operation / Logic